HTC-K-VP-L/2000
Converter: CO2 and temperature; Usup: 24VDC; 0÷50°C; Temp: 0÷50°C
Converter: CO2 and temperature; Usup: 24VDC; 0÷50°C; Temp: 0÷50°C
IR601/3
Sensor: gas; carbon dioxide (CO2); Range: 0÷2%; Connection: 3/4"
Sensor: gas; carbon dioxide (CO2); Range: 0÷2%; Connection: 3/4"
ME4-SO2
Sensor: gas; Sulphur dioxide (SO2); Range: 0÷20ppm
Sensor: gas; Sulphur dioxide (SO2); Range: 0÷20ppm
MP-3B
Sensor: gas; ethylic alcohol (C2H5OH); Range: 0÷500ppm
Sensor: gas; ethylic alcohol (C2H5OH); Range: 0÷500ppm
MQ-5
Sensor: gas; methane (CH4),propane-butane (LPG); MQ-5
Sensor: gas; methane (CH4),propane-butane (LPG); MQ-5
MQ-7B
Sensor: gas; carbon monoxide (CO); Range: 10÷500ppm; MQ-7B
Sensor: gas; carbon monoxide (CO); Range: 10÷500ppm; MQ-7B
MQ137
Sensor: gas; ammonia (NH3); Range: 5÷500ppm; MQ-137
Sensor: gas; ammonia (NH3); Range: 5÷500ppm; MQ-137
MQ-2
Sensor: gas; smoke,combustible gases; Range: 300÷10000ppm; MQ-2
Sensor: gas; smoke,combustible gases; Range: 300÷10000ppm; MQ-2
MQ138
Sensor: gas; acetone,alcohol,toluene,hydrogen (H2); MQ-138
Sensor: gas; acetone,alcohol,toluene,hydrogen (H2); MQ-138
MH-Z14A-5KPPM
Sensor: gas; carbon dioxide (CO2); Range: 0÷5000ppm
Sensor: gas; carbon dioxide (CO2); Range: 0÷5000ppm
ME2-O2-20MM
Sensor: gas; oxygen (O2); Range: 0÷25% VOL; ME2; Press-Fit
Sensor: gas; oxygen (O2); Range: 0÷25% VOL; ME2; Press-Fit
MP905
Sensor: gas; alcohol,benzene,smoke,methanal (CH2O),toluene
Sensor: gas; alcohol,benzene,smoke,methanal (CH2O),toluene
MQ-6
Sensor: gas; propane-butane (LPG); Range: 300÷10000ppm; MQ-6
Sensor: gas; propane-butane (LPG); Range: 300÷10000ppm; MQ-6
MQ-9B
Sensor: gas; methane (CH4),carbon monoxide (CO); MQ-9B
Sensor: gas; methane (CH4),carbon monoxide (CO); MQ-9B
MQ-8
Sensor: gas; hydrogen (H2); Range: 100÷1000ppm; MQ-8
Sensor: gas; hydrogen (H2); Range: 100÷1000ppm; MQ-8
MQ135
Sensor: gas; ammonia (NH3),benzene; Range: 10÷10000ppm; MQ-135
Sensor: gas; ammonia (NH3),benzene; Range: 10÷10000ppm; MQ-135
MQ-4
Sensor: gas; methane (CH4); Range: 300÷10000ppm; MQ-4
Sensor: gas; methane (CH4); Range: 300÷10000ppm; MQ-4
IR21EM
Sensor: gas; carbon dioxide (CO2); Range: 0÷5%; Ø20x16.6mm
Sensor: gas; carbon dioxide (CO2); Range: 0÷5%; Ø20x16.6mm
HCEM-06D
Converter: CO2, temperature and humidity; Usup: 24VDC; -40÷125°C
Converter: CO2, temperature and humidity; Usup: 24VDC; -40÷125°C
HCEM-05D
Converter: CO2, VOC; Usup: 24VDC; -20÷50°C; 120x80x25mm; 24VAC
Converter: CO2, VOC; Usup: 24VDC; -20÷50°C; 120x80x25mm; 24VAC